4.1.3. Tachymetric Set
The tachymetric set or total station measurement sequence is initiated by
means of the menu function Input > Tachymetric Set.
Prior to each tachymetric set, a station must be selected or newly defined in
this dialog. If the number of a new station is entered, GART-2000®
CE switches to
the dialog Enter
Stations. If these data are confirmed with <OK>,
the Measurement Registration window - adjusted for the relevant tachymetric set
- opens up for the selected station.
After the measurement
in the direction of the 1st target of the first set has been triggered by the
button <M> (measurement of all
magnitudes) or <Angle> (angle
measurement only) and the measurements have been subsequently saved with <OK>,
the digit 2 is set automatically as the target. If the <No
Save.> button is pressed, the measurement dialog is displayed once
again and the measurement can be repeated.
When the measurement in the normal telescope setting (Face 1) has been
completed, the measurement in the reverse telescope setting (Face 2) can be
started by turning the telescope and re-measuring the last target. The further
targets of the set are then presented in reverse order. Alternatively, the <Face 2> button
can be clicked. When all the targets of the 1st set have been measured in
both telescope settings,
GART-2000®
CE
automatically proposes measuring the 2nd set.
By clicking the <Station>
button, the values set in the dialog
Enter Stations can be modified. During the tachymetric set measurement,
the instrument constants for the axes are not applied since measurement is
performed with two telescope settings.