4.3.8.
Instrument Errors
The function Calculate > Instrument errors serves to determine the
instrument errors of a total station. When the function is called up, the
instrument for which the error determination is to be carried out is queried
first of all. Subsequently, the measurements take place in the following
order:
1. Target Face 1 (horizontal sight)
1. Target Face 2 (horizontal sight)
2. Target Face 1 (steep sight)
2. Target Face 2 (steep sight)
The measurement is triggered by the button <Measure>.
The angles are displayed in the fields H and
V. By pressing the button <Save>,
the measured values are accepted. The same procedure occurs for the other
settings. After each measurement the errors to be determined are recalculated
and displayed. The button >>
enables remote control in the case of servo-driven instruments.
The dialog is quitted with the button <X>.
The user is then asked if the instrument errors determined are to be
adopted.