4.5.3.4. Coordinates Constatns
The values in the Initial > Constants > Coordinates define within which
tolerances GART-2000®
CE saves
coordinates under the same point number without notice.
In the fields East, North
and Height the tolerances for
the east, north and height coordinates can be entered. The default setting is 2
cm. Alternatively to the east and north tolerances the Plane distance can be
used. GART-2000®
CE
will apply the lowest value.
If a new coordinate with the same point number as an existing coordinate exceeds
the tolerances, GART-2000®
CE displays
the Double Coordinates dialog
showing the coordinate differences. The new coordinate can be saved or ignored.
If the point code or
the marker type of a new point differs to those of an existing point with the
same point number, GART-2000®
CE displays
the New Code or Marker Type
dialog.
This dialog shows the
code and marker type of the existing point in the first two rows and the code
and marker type of the new point in the last two rows.
With the <Change> button the